Air Injection Technology
|
Power Augmentation of the Siemens-Westinghouse Gas Turbines with Humid Air Injection (HAI) and Dry Air Injection (DAI)
Predicted Power Augmentation of SW 501FD Gas Turbine with HAI and DAI
(@Sea Level, 95F, 60% RH )
| |
CT-Humid
Air Injection |
CT-Humid
Air Injection |
CT-Dry
Air Injection |
Simple CT |
| Total Moisture % of Air to
Combustor |
9.0 |
5.5 |
- |
- |
| Net Power, MW |
211 |
199.5 |
196 |
169.7 |
| Net Heat Rate, Btu/kWh
(LHV) |
8,580 |
8,880 |
9,000 |
9,280 |
| Incremental Power, MW |
41.3** |
29.8** |
26.3** |
Base |
| Incremental Heat rate,
Btu/kWh |
5,705 |
6,600 |
7,200 |
Base |
** Restricted by the assumed compressor
surge margin.
Predicted Power Augmentation of SW 501D5A Gas Turbine with HAI and DAI
(@Sea Level, 95F, 60% RH )
| |
CT-Humid
Air Injection |
CT-Humid
Air Injection |
CT-Dry
Air Injection |
Simple CT |
| Total Moisture % of Air to
Combustor |
9.0 |
5.5 |
- |
- |
| Net Power, MW* |
137.5 |
129.3 |
121.5 |
105.6 |
| Net Heat Rate, Btu/kWh
(LHV) |
9,040 |
9,395 |
9,795 |
10,050 |
| Incremental Power, MW |
31.9** |
23.7** |
15.9** |
Base |
| Incremental Heat rate,
Btu/kWh |
5,700 |
6,480 |
8,100 |
Base |
** Restricted by the assumed compressor
surge margin.

|
Contact:
Dr. Rodney R. Gay
Dr. Michael Nakhamkin
|
Telephone:
(805) 686-4500
(908) 658-4815
|
Fax:
(805) 686-5154
(908) 658-4429
|
E-Mail:
RodneyGay @ ESPCinc.com Mnakhamkin @ ESPCinc.com
|
|