Air Injection Technology
|
Power
Augmentation of the General Electric Combustion Turbines
with Humid Air Injection (HAI) and Dry Air Injection
(DAI)
Predicted Power Augmentation of GE PG7241 (FA) CT with HAI and DAI
(@Sea Level, 95F, 60% RH )
| |
CT-Humid
Air Injection |
CT-Humid
Air Injection |
CT-Dry
Air Injection |
Simple CT |
| Total Moisture % of Air to
Combustor |
7.5 |
5.5 |
- |
- |
| Net Power, MW |
182.6 |
177 |
166.4 |
150.4 |
| Net Heat Rate, Btu/kWh
(LHV) |
9,160 |
9,380 |
9,720 |
9,760 |
| Incremental Power, MW |
32.2 |
26.6 |
16.0 |
Base |
| Incremental Heat rate,
Btu/kWh |
6,360 |
7,230 |
9,345 |
Base |



Predicted Power Augmentation of GE PG7121 (EA) CT with HAI and DAI
(@Sea Level, 95F, 60% RH )
| |
CT-Humid
Air Injection |
CT-Humid
Air Injection |
CT-Dry
Air Injection |
Simple CT |
| Total Moisture % of Air to
Combustor |
11.0 |
9.0 |
- |
- |
| Net Power, MW* |
106.2 |
103.9 |
88.6 |
74.3 |
| Net Heat Rate, Btu/kWh
(LHV) |
9,380 |
9,440 |
10,640 |
9,760 |
| Incremental Power, MW |
31.9** |
29.6** |
14.3** |
Base |
| Incremental Heat rate,
Btu/kWh |
8,495 |
8,640 |
15,210 |
Base |
** Restricted by the assumed compressor
surge margin

|
Contact:
Dr. Rodney R. Gay
Dr. Michael Nakhamkin
|
Telephone:
(805) 686-4500
(908) 658-4815
|
Fax:
(805) 686-5154
(908) 658-4429
|
E-Mail: